Hybrid Assistant Report


High Voltage Battery Health

Note: Statistics from this paragraph are limited to the HV Check time span, not the whole trip

HV Battery
Number of Blocks 17
Number of samples 2105
Average sample time 0.32
Start time 08/02/2017 11:55:49
End time 08/02/2017 12:07:00
Duration 11:11

Block values

15.3 15.63 15.97 16.3 16.63 16.97 17.3 30 40 50 60 70 80 90 11:55:49 11:57:03 11:58:18 11:59:33 12:00:47 12:02:02 12:03:17 12:04:31 12:05:46 12:07:00 Time V SOC % Block 1 Block 2 Block 3 Block 4 Block 5 Block 6 Block 7 Block 8 Block 9 Block 10 Block 11 Block 12 Block 13 Block 14 Block 15 Block 16 Block 17 SOC

Voltage Delta

15.3 15.5 15.7 15.9 16.1 16.3 16.5 16.7 16.9 17.1 17.3 0 0.2 0.4 0.6 0.8 1 1.2 1.4 1.6 1.8 2 11:55:49 11:57:03 11:58:18 11:59:33 12:00:47 12:02:02 12:03:17 12:04:31 12:05:46 12:07:00 Time V Delta Max Average Min Delta

Blocks stats
Block Min Max % Time @ Min V Avg Bias Max Bias Avg Local Delta
1 15.66 16.88 0.00 0.05 0.13 0.07
2 15.61 16.81 0.00 0.10 0.18 0.12
3 15.71 16.88 0.00 0.02 0.08 0.12
4 15.66 16.83 0.00 0.07 0.15 0.07
5 15.66 16.88 0.00 0.05 0.13 0.07
6 15.63 16.81 0.00 0.09 0.15 0.11
7 15.71 16.88 0.00 0.02 0.08 0.10
8 15.68 16.85 0.00 0.05 0.13 0.07
9 15.71 16.90 0.00 0.01 0.08 0.08
10 15.71 16.85 0.00 0.05 0.12 0.09
11 15.73 16.88 0.00 0.01 0.05 0.10
12 15.68 16.83 0.00 0.06 0.14 0.08
13 15.63 16.83 0.00 0.07 0.15 0.06
14 15.63 16.78 0.00 0.10 0.15 0.10
15 15.68 16.85 0.00 0.05 0.10 0.08
16 15.66 16.83 0.00 0.07 0.15 0.06
17 15.66 16.90 0.00 0.05 0.13 0.05

Global stats
Minimum observed battery voltage 267 V
Maximum observed battery voltage 286 V
Minimum observed block voltage 15.61 V
Maximum observed block voltage 16.90 V
Maximum Delta 0.18 V
Average Delta 0.11 V
Minimum observed current 1.47 A
Maximum observed current 5.22 A
Minimum observed SOC 51.4%
Maximum observed SOC 61.6%
Delta SOC 10.2%
Energy 713mAh
Estimated Capacity 6.99Ah

Delta Thresholds
Threshold Consecutive Samples
0.2 0
0.45 0
0.7 0
0.95 0
1.2 0