Hybrid Assistant Report


High Voltage Battery Health

Note: Statistics from this paragraph are limited to the HV Check time span, not the whole trip

HV Battery
Number of Blocks 14
Number of samples 1476
Average sample time 0.28
Start time 08/02/2017 17:00:05
End time 08/02/2017 17:06:59
Duration 6:53

Block values

14.6 14.93 15.27 15.6 15.93 16.27 16.6 30 40 50 60 70 80 90 17:00:05 17:00:51 17:01:37 17:02:23 17:03:09 17:03:55 17:04:41 17:05:27 17:06:13 17:06:59 Time V SOC % Block 1 Block 2 Block 3 Block 4 Block 5 Block 6 Block 7 Block 8 Block 9 Block 10 Block 11 Block 12 Block 13 Block 14 SOC

Voltage Delta

14.6 14.8 15 15.2 15.4 15.6 15.8 16 16.2 16.4 16.6 0 0.2 0.4 0.6 0.8 1 1.2 1.4 1.6 1.8 2 17:00:05 17:00:51 17:01:37 17:02:23 17:03:09 17:03:55 17:04:41 17:05:27 17:06:13 17:06:59 Time V Delta Max Average Min Delta

Blocks stats
Block Min Max % Time @ Min V Avg Bias Max Bias Avg Local Delta
1 14.78 16.29 0.20 0.20 0.34 0.03
2 14.78 16.32 0.00 0.19 0.35 0.06
3 14.72 16.30 23.71 0.23 0.42 0.07
4 14.76 16.30 1.22 0.21 0.38 0.05
5 14.73 16.31 5.42 0.20 0.41 0.07
6 14.72 16.29 38.35 0.23 0.39 0.06
7 14.74 16.31 3.25 0.21 0.41 0.24
8 15.09 16.40 0.00 0.00 0.00 0.41
9 14.77 16.30 1.08 0.19 0.37 0.22
10 14.74 16.31 2.71 0.22 0.38 0.05
11 14.70 16.31 12.74 0.22 0.42 0.05
12 14.75 16.33 0.07 0.18 0.35 0.06
13 14.78 16.32 0.00 0.19 0.37 0.06
14 14.76 16.31 2.98 0.21 0.35 0.06

Global stats
Minimum observed battery voltage 207 V
Maximum observed battery voltage 228 V
Minimum observed block voltage 14.70 V
Maximum observed block voltage 16.40 V
Maximum Delta 0.42 V
Average Delta 0.24 V
Minimum observed current 0.00 A
Maximum observed current 12.00 A
Minimum observed SOC 59.2%
Maximum observed SOC 71.0%
Delta SOC 11.8%
Energy output 102.2 Wh

Delta Thresholds
Threshold Consecutive Samples
0.2 777
0.45 0
0.7 0
0.95 0
1.2 0